Cost effective passive catalytic sensors to detect potentially hazardous concentrations of flammable gas and vapour in air up to 100% LEL. Available as Standard (ST), Poison Resistant (PRP), High Temperature (HT) versions with a complete range of accessories and junction boxes to meet virtually all industrial applications. Series 47K sensors used in combination with MSA Controllers fully meet the requirements of ATEX Directive 94/9/EC, including performance approval, and being SIL 2 capable they can be used as part of a safety related system. ATEX II 2G Ex d IIC T3/T4/T6, II 2D Ex tD A21 IP6X T85°C/T135°C/T200°Cincluding performance approval, SIL 2 EAC, performance approval in RU, KZ, BY

The PrimaX I gas transmitter detects a wide range of toxic gases and oxygen using an electrochemical sensor technology. Innovative enclosure design, ease of use, fast installation and being suitable for both indoor and outdoor installations make the PrimaX I transmitter your choice for versatile gas detection. The large display with clear plain text provides information at a glance. Calibration is easily performed using the built-in keypad or via HART digital protocol. The plug-in replacement sensors and an integral backplate enable fast and easy installation.PrimaX I comes as general purpose or intrinsically safe design in a robust anti-static, reinforced nylon housing with standard 4–20 mA output and optional HART capability. SIL 2 compliance is approved by TUV. ATEX II 1G Ex ia IIC T4 Ga, II 2D Ex ia IIIC T130 °C Db IP54, SIL 2 HART registered IECEx, UL, INMETRO, EAC, performance approval in RU, KZ, BY

The PrimaX P gas transmitter is suited to a wide range of indoor and outdoor applications for the detection of combustible gases (catalytic combustion sensor), toxic gases or oxygen (electrochemical sensors). The PrimaX P features an innovative custom designed enclosure with integral 4-way keypad for ease of use. The large LCD with clear plain text provides information at a glance and the additional LEDs give a clear status indication. The plug-in replacement sensors and an integral backplate enable fast and easy installation. PrimaX P comes as flameproof design in a coated aluminium enclosure with standard 4–20 mA output and optional HART and relays capability. SIL 2 compliance is approved by TUV. ATEX II 2G Ex d ia [ia] IIC T4 Ga, II 2D Ex tb ia [ia] IIIC T130 °C Db IP67 including performance approval, SIL 2, HART registered IECEx, UL, CSA, CCCF, INMETRO, EAC, performance approval in RU, KZ, BY

The PrimaX IR offers hydrocarbon detection in LEL range using infrared absorption technology through the patent-pending PrimaX IR dual source design. A redundant IR source provides reliability and uninterrupted monitoring should a source failure occur. The 316 stainless steel, IP67-rated, rugged housing protects the PrimaX IR from environmental extremes. Standard 4–20 mA output with HART capability offers user-friendly set-up, calibration diagnostics, and maintenance. A unique environmental guard with patent-pending clamshell design provides convenient installation in tight locations. ATEX II 2G Ex d IIC T4 Gb, II 2D Ex tb IIIC T130°C Db IP67, SIL 2 IECEx, CCCF, INMETRO, EAC, performance approval in RU, KZ, BY

ULTIMA MOS-5 and MOS-5E detect ppm levels of hydrogen sulphide (H₂S), providing status indication and alarm outputs. Their performance is based on their metal oxide semiconductor sensor with unique technical parameters. High tolerance for a broad range of temperatures, humidity levels, as well as short-term high H₂S concentrations and very low cross sensitivity to common gases make these detectors ideal for installation in harsh environments. The ULTIMA MOS-5 provides analogue 4–20 mA and 3 relay outputs in a stainless steel housing. The ULTIMA MOS-5E incorporates analogue 4–20 mA and three open collector outputs in an aluminum housing. HART and Modbus communication enable complete status and control capability in the control room. ATEX II 2GD EEx d IIB+H₂ T5, SIL 2 and SIL 3, IP66 HART registered (ULTIMA MOS-5) ATEX II 2G EEx d e m IIC T4, SIL 3, IP66/67 (ULTIMA MOS-5E) FM, CSA, EAC, performance approval in RU, KZ, BY

The cost-effective fixed installation gas monitors ULTIMA XL and XT with HART field communications protocol use well proven catalytic, electrochemical and infrared technologies for detection of combustible and toxic gases and for oxygen deficiency. The interchangeable smart sensors can be changed under power without declassifying a hazardous area. With the non-display ULTIMA XL/XT gas monitors the user has multiple calibration options: the handheld HART communicator, a controller or laptop which communicates via a dedicated HART Software and local internal LEDs and push-buttons. ULTIMA XL is explosion-proof with a stainless steel enclosure, while ULTIMA XT uses a general purpose, water and corrosion resistant polycarbonate housing. ATEX II 2 (2) G Ex d (ib) IIC T6, II 3 (2) G Ex nA (ib) IIC T6, IP66 (ULTIMA XL) IECEx, FM, INMETRO, EAC, performance approval in RU, KZ, BY

The ULTIMA XE and XIR provide continuous monitoring of combustible and toxic gases and oxygen deficiency using catalytic, electrochemical and infrared sensor technologies. They are suitable for almost all applications in virtually any type of industry. A large easy to read LCD shows the gas reading and gas type as well as clear text status messages. The ULTIMA X series is powered from 24 VDC with a 4–20 mA output signal and optional on board status LED’s and/or output relays. Smart sensor technology allows sensor disconnect and replacement under power in hazardous locations. ULTIMA XE gas monitors are also available with HART field communications protocol. The ULTIMA XA comes in a rugged plastic general purpose enclosure. It is available with 4–20 mA analogue output or with optional HART protocol. ATEX II 2G EEx d IIC T4, including performance approval SIL 2 (ULTIMA XE) AT EX II 2G EEx d IIC T5/T6, including performance approval SIL 2 (ULTIMA XIR) IECEx, FM, UL, CSA, CCCF, INMETRO, EAC, performance approval in RU, KZ, BY

Designed with advanced ultraviolet (UV) and infrared (IR) sensing technology, the FlameGard 5 Series represents the state-of-the-art in secure flame monitoring. The FlameGard 5 MSIR, a multi-spectral infrared detector designed to detect hydrocarbon fires, features breakthrough Neural Network Technology (NNT) for reliable discrimination between actual flames and nuisance false alarm sources within a distance of up to 70 m. FlameGard 5 UV/IR is designed to detect hydrocarbon fires within 15 m, FlameGard 5 UV/IR-H₂ is optimized to detect hydrogen based flames, and FlameGard 5 UV/IR-E with stainless steel housing and Ex e wiring compartment enables high level of resistance in harsh environments. The FlameGard 5 Series flame detectors provide standard 4–20 mA output with optional relays or HART and Modbus digital communication. Suitable for a wide range of applications in the production, transport and processing. ATEX II 2G Ex d IIC T5 Gb, II 2D Ex tb IIIC T100 °C Db, SIL 3 HART registered (MSIR, UV/IR) IECEx, FM, CSA ATEX II 2G Ex d e IIC T4/T5 Gb, II 2D Ex tb IIIC T135 °C /100 °C Db, IP6X (UV/IR-E) EAC, Russian Fire Approval

The ULTIMA OPIR-5 open path hydrocarbon gas transmitter provides continuous monitoring of methane and propane gas concentrations based on advanced infrared sensor technology features. The dual detection range enables sensitivity to both small (ppm•m) and large (LEL•m) gas leaks. The ULTIMA OPIR-5 includes continuous self-check monitoring for fail to safe operation. Automatic gain control compensates for dirty optics, rain, and fog. The result is precision accuracy with exceptional reliability in harsh environments and improved false alarm rejection with an optical path length of up to 150 m. Standard analogue output 4–20 mA with HART capability, relays and RS485 Modbus allow to connect ULTIMA OPIR-5 to standard industrial controllers. ATEX II 2G D Ex d IIB+H₂ T4 Gb, II 2D Ex tb IIIC T135 °C Db IP66/67 SIL 3, HART registered IECEx, FM, CSA, EAC, performance approval in RU, KZ, BY

The OBSERVER-i is the world’s first ultrasonic gas leak detector equipped with Artificial Neural Network (ANN) real-time broadband acoustic sound processing technology. Used to detect leaks from high-pressure systems with a maximum coverage radius of 28 metres, the OBSERVER-i responds to the airborne ultrasound generated from gas releases in open ventilated areas, where traditional methods of detection may be difficult. The Senssonic™ patented self-test ensures failsafe operation and a three digit LED display showing actual ultrasonic level value (in dB) and alarm indication. Standard 4–20 mA output with HART capability and output relays can control additional action in case of alarm or fault condition. ATEX Ex d ia IIB+H₂ Gb T6, Ex tb IIIC T85°C Db (Ta = –40°C to +60°C) EAC

The OBSERVER-i is the world’s first ultrasonic gas leak detector equipped with Artificial Neural Network (ANN) real-time broadband acoustic sound processing technology. Used to detect leaks from high-pressure systems with a maximum coverage radius of 28 metres, the OBSERVER-i responds to the airborne ultrasound generated from gas releases in open ventilated areas, where traditional methods of detection may be difficult. The Senssonic™ patented self-test ensures failsafe operation and a three digit LED display showing actual ultrasonic level value (in dB) and alarm indication. Standard 4–20 mA output with HART capability and output relays can control additional action in case of alarm or fault condition. ATEX Ex d ia IIB+H₂ Gb T6, Ex tb IIIC T85°C Db (Ta = –40°C to +60°C) EAC

The OBSERVER-i is the world’s first ultrasonic gas leak detector equipped with Artificial Neural Network (ANN) real-time broadband acoustic sound processing technology. Used to detect leaks from high-pressure systems with a maximum coverage radius of 28 metres, the OBSERVER-i responds to the airborne ultrasound generated from gas releases in open ventilated areas, where traditional methods of detection may be difficult. The Senssonic™ patented self-test ensures failsafe operation and a three digit LED display showing actual ultrasonic level value (in dB) and alarm indication. Standard 4–20 mA output with HART capability and output relays can control additional action in case of alarm or fault condition. ATEX Ex d ia IIB+H₂ Gb T6, Ex tb IIIC T85°C Db (Ta = –40°C to +60°C) EAC

The OBSERVER-i is the world’s first ultrasonic gas leak detector equipped with Artificial Neural Network (ANN) real-time broadband acoustic sound processing technology. Used to detect leaks from high-pressure systems with a maximum coverage radius of 28 metres, the OBSERVER-i responds to the airborne ultrasound generated from gas releases in open ventilated areas, where traditional methods of detection may be difficult. The Senssonic™ patented self-test ensures failsafe operation and a three digit LED display showing actual ultrasonic level value (in dB) and alarm indication. Standard 4–20 mA output with HART capability and output relays can control additional action in case of alarm or fault condition. ATEX Ex d ia IIB+H₂ Gb T6, Ex tb IIIC T85°C Db (Ta = –40°C to +60°C) EAC